EasyShort – Fixed prosthetic solution

All the abutments, analogue and transfers are made of titanium grade 5 (Ti6Al4V). The fastening screw ELPSC1 is included in the packaging of the abutments.Tighten to 30 N*cm using the torque ratchet wrench ELPSK1 or ELPSK2 with the torque ratchet ELKWD.

Titanium abutment for cemented prosthesis

Moncone-in-titanio-per-protesi-cementata

Code
ELDTA

 

Cylindrical titanium abutment for cemented prosthesis

Code
ELDTA2

 

Angled titanium abutments

Code Angle Type Colour
ELA15A 15° A Green
ELA15B 15° B Purple
ELA25A 25° A Blue
ELA25B 25° B Gold

Angled titanium abutments for test

Code Angle Type Colour
ELA15AC 15° A Green
ELA15BC 15° B Purple
ELA25AC 25° A Blue
ELA25BC 25° B Gold


angolati
Note: The difference between abutments type ‘A’ and type ‘B’, consists in a rotation of 22,5° of the octagon with respect to its axis of reference and that of inclination. This allows you to double the chances of placement of such abutments.
 

Peek temporary abutments

Code Angle Type
ELDTAP
ELA15AP 15° A
ELA15BP 15° B
ELA25AP 25° A
ELA25BP 25° B

Shouldered abutments

Monconi-a-spalla

Code Ø (mm) Shoulder (mm) For implants (mm)
EDS5010 5.0 1.0 Ø 4.0
EDS5015 5.0 1.5 Ø 4.0
EDS5020 5.0 2.0 Ø 4.0
EDS5510 5.5 1.0 Ø 4.0
EDS5515 5.5 1.5 Ø 4.0
EDS5520 5.5 2.0 Ø 4.0
ENS5510 5.5 1.0 Ø 4.75 e Ø 5.25
ENS5515 5.5 1.5 Ø 4.75 e Ø 5.25
ENS5520 5.5 2.0 Ø 4.75 e Ø 5.25
ENS6010 6.0 1.0 Ø 4.75 e Ø 5.25
ENS6015 6.0 1.5 Ø 4.75 e Ø 5.25
ENS6020 6.0 2.0 Ø 4.75 e Ø 5.25

 

Milling titanium abutment

Moncone-in-titanio-fresabile

Code For implants
EDMFD Ø 4.0 mm
ENMFD Ø 4.75 e Ø 5.25 mm


 

Castable abutment

ELCPXI

Code
ELCPXI

 

Platform Switching abutments

Monconi-Platform-Switching

Code Ø (mm) Angle
ELSP45 4.5 -
ELSP4515 4.5 15°
ELSP55 5.5 -
ELSP5515 5.5 15°

 

Screw-retained abutment for cemented prosthesis

Moncone-avvitabile-per-protesi-cementata

Code H mm Colour
ELMAC1 Short 7.2 Gold
ELMAC2 Medium 8.7 Blue
ELMAC3 Long 10.2 Green

Tighten to 30 N*cm using the wrench  ELMAK with the torque ratchet ELKWD.

 

Castable for screw-retained abutments

Calcinabile-per-moncone-avvitabile

Code Type For implants
EDCAM1 Short Ø 4.0 mm
EDCAM2 Medium Ø 4.0 mm
EDCAM3 Long Ø 4.0 mm
ENCAM1 Short Ø 4.75 e Ø 5.25 mm
ENCAM2 Medium Ø 4.75 e Ø 5.25 mm
ENCAM3 Long Ø 4.75 e Ø 5.25 mm

 

Analogue for the screw-retained abutment

Analogo-del-moncone-avvitabile

Code Type Colour For implants
EDMAC1A Short Gold Ø 4.0 mm
EDMAC2A Medium Blue Ø 4.0 mm
EDMAC3A Long Green Ø 4.0 mm
ENMAC1A Short Gold Ø 4.75 e Ø 5.25 mm
ENMAC2A Medium Blue Ø 4.75 e Ø 5.25 mm
ENMAC3A Long Green Ø 4.75 e Ø 5.25 mm

 

Impression transfer technique for the screw-retained abutment

To transfer the location of the screw-retained abutment onto a casting, proceed by screwing the abutment on the implant. Then proceed with the impression using a slotted spoon. Insert the screw-retained abutment analogue EDMAC or ENMAC of the corresponding abutment lenght. Now it is possible to send the impression to the laboratory.

 

Implant Analogue

Analogo-impianto-dip

Code Colour For implants (mm)
EDAN Gold Ø 4.0
ENAN Green Ø 4.75 e Ø 5.25

 

Implant transfer

Transfer-per-impianto-dip

Code Colour For implants (mm)
EDTRA Gold Ø 4.0
ENTRA Green Ø 4.75 e Ø 5.25

 

Implant impression transfer technique

To transfer the location of the fixture onto a casting, proceed by inserting the implant transfer EDTRA or ENTRA in the implant and secure it with the long fastening screw ELPSC2 included in the packaging of the transfer. Tighten using the screwdrivers ELCSK1 or ELCSK2 or the contra-angle wrench ELPSCAK. Then proceed with the impression using a slotted spoon. Before removing the impression, loosen the fastening screw releasing the transfer. Insert the implant analogue EDAN or ENAN, assembling it to its transfer EDTRA or ENTRA using the fastening screw previously loosened. Now it is possible to send the impression to the laboratory.